For professional use · Aqua Purify PRO · Available on quotation
Five models for planning your reverse osmosis capacity
Kinetico Purecleer COMPACT HL is a direct-flow reverse osmosis series for professional and industrial water treatment installations. Five variants, from COMPACT HL 400 to COMPACT HL 1200, use between two and six 4040 membranes within a common frame measuring 1,682 × 640 × 634 mm. The series provides 99% salt rejection, adjustable recovery up to 75% and a maximum feedwater salinity of 3,500 ppm. Electronic pump control is provided across the series. Available from AquaPurify on quotation, these systems allow production capacity to be considered alongside actual site demand, water quality and the available electrical and hydraulic connections.
Series highlights
- Five variants in a common frame size to compare production capacities during installation planning.
- Between two and six 4040 membranes, depending on the model, with salt rejection of 99%.
- Recovery adjustable up to 75%, with the appropriate setting assessed for feedwater and operating conditions.
- Maximum feedwater salinity of 3,500 ppm.
- Electronic pump control and a three-phase 380 V, 50 Hz electrical supply.
Choosing a model
The series comprises COMPACT HL 400, HL 600, HL 800, HL 1000 and HL 1200, with respective flow rates of 400, 600, 800, 1,000 and 1,200 L/h. Compare the 24-hour volume, membrane count and connections in the table. The HL 1200 has 1-inch BSP product and reject connections; the other models have 1/2-inch BSP connections.
Technical specifications by model
Manufacturer technical specifications. The 24-hour volume corresponds to 24 hours of production at the indicated hourly flow rate.| Specification | COMPACT HL 400 | COMPACT HL 600 | COMPACT HL 800 | COMPACT HL 1000 | COMPACT HL 1200 |
|---|
| Technology | Direct-flow reverse osmosis | Direct-flow reverse osmosis | Direct-flow reverse osmosis | Direct-flow reverse osmosis | Direct-flow reverse osmosis |
|---|
| Maximum feedwater salinity (ppm) | 3,500 ppm | 3,500 ppm | 3,500 ppm | 3,500 ppm | 3,500 ppm |
|---|
| Production flow rate (L/h) | 400 L/h | 600 L/h | 800 L/h | 1,000 L/h | 1,200 L/h |
|---|
| 24-hour production volume (L) | 9,600 L/24 h | 14,400 L/24 h | 19,200 L/24 h | 24,000 L/24 h | 28,800 L/24 h |
|---|
| Membranes | 2 × 4040 | 3 × 4040 | 4 × 4040 | 5 × 4040 | 6 × 4040 |
|---|
| Salt rejection (%) | 99 % | 99 % | 99 % | 99 % | 99 % |
|---|
| Recovery rate | Adjustable up to 75% | Adjustable up to 75% | Adjustable up to 75% | Adjustable up to 75% | Adjustable up to 75% |
|---|
| Maximum operating pressure (kg/cm²) | 19 kg/cm² | 19 kg/cm² | 19 kg/cm² | 19 kg/cm² | 19 kg/cm² |
|---|
| Minimum dynamic inlet pressure (kg/cm²) | 2 kg/cm² | 2 kg/cm² | 2 kg/cm² | 2 kg/cm² | 2 kg/cm² |
|---|
| Feedwater temperature (°C) | 3–35 °C | 3–35 °C | 3–35 °C | 3–35 °C | 3–35 °C |
|---|
| Feedwater pH | 3–11 | 3–11 | 3–11 | 3–11 | 3–11 |
|---|
| Feedwater chlorine (ppm) | < 0.1 ppm | < 0.1 ppm | < 0.1 ppm | < 0.1 ppm | < 0.1 ppm |
|---|
| Installed power (kW) | 2.2 kW | 2.2 kW | 2.2 kW | 2.2 kW | 2.2 kW |
|---|
| Electrical supply | III 380 V · 50 Hz | III 380 V · 50 Hz | III 380 V · 50 Hz | III 380 V · 50 Hz | III 380 V · 50 Hz |
|---|
| Electronic pump control | Yes | Yes | Yes | Yes | Yes |
|---|
| Feedwater connection | 1″ BSP female | 1″ BSP female | 1″ BSP female | 1″ BSP female | 1″ BSP female |
|---|
| Permeate connection | ½″ BSP | ½″ BSP | ½″ BSP | ½″ BSP | 1″ BSP |
|---|
| Reject connection | ½″ BSP | ½″ BSP | ½″ BSP | ½″ BSP | 1″ BSP |
|---|
| Dimensions H × W × D (mm) | 1,682 × 640 × 634 mm | 1,682 × 640 × 634 mm | 1,682 × 640 × 634 mm | 1,682 × 640 × 634 mm | 1,682 × 640 × 634 mm |
|---|
Preparing your installation
Sizing should start with water analysis and the consumption profile, including peak demand and the required water quality. Check the 3,500 ppm maximum feedwater salinity, chlorine, pH and temperature limits, and the minimum dynamic inlet pressure of 2 kg/cm². Provide a three-phase 380 V, 50 Hz supply for the 2.2 kW installed power, a 1 inch BSP female feed connection and drainage suited to the reject flow. Permeate and reject connection sizes depend on the model. Maintenance access, any necessary pretreatment and associated equipment must be defined during the technical assessment.
Maintenance and monitoring
The maintenance plan depends on feedwater quality, operating settings and usage conditions. Follow the instructions applicable to the supplied equipment and monitor pressure, flow, produced water quality, membrane condition and connections. Recovery settings and pump operation should also be reviewed as part of routine technical monitoring. Cleaning and consumable replacement requirements must be determined for the installation.
Optional accessory
The Purecleer blending kit may be assessed as an optional accessory for the project. It is not included in the base description; suitability, compatibility and any addition to the supply must be confirmed in the quotation.
Technical documentation
Download the data sheet — PDF in English
Visit the manufacturer’s page
Frequently asked questions
How do I choose between the five COMPACT HL models?
Compare hourly and daily water demand with the specifications of each variant, then assess the selection against water analysis and site constraints. Models use between two and six membranes.
Can the system always run at 75% recovery?
Recovery is adjustable up to 75%; the suitable operating setting depends on feedwater and the installation. It must be determined during the technical assessment and commissioning.
Which services and connections are required?
The series requires three-phase 380 V, 50 Hz power and a 1 inch BSP female feedwater connection. Permeate and reject connections are 1/2 inch BSP on HL 400 through HL 1000 and 1 inch BSP on HL 1200. Reject drainage and maintenance access must be included in the installation assessment.
Available on quotation
Your quotation specifies the model, scope of supply, availability and delivery lead time.
Request a quotation