Skip to Content
VIQUA

VIQUA VH

VIQUA VH combines a compact UV chamber with constant-current electronic control. Choose a standard model, an F assembly with integrated prefiltration, or a -V model for NSF/ANSI 55 Class B supplemental treatment. Models carrying the M designation include a UV sensor.

ModelFlow / UV dosePower supply
VH15019 L/min — 30 mJ/cm²230V EU (CE7/7)
VH20034 L/min — 30 mJ/cm²230V EU (CE7/7)
VH41070 L/min — 30 mJ/cm²230V EU (CE7/7)
VH410M70 L/min — 30 mJ/cm²230V EU (CE7/7)
VH200-F1034 L/min — 30 mJ/cm²230V EU (CE7/7)
VH410-F2070 L/min — 30 mJ/cm²230V EU (CE7/7)
VH200-F1234 L/min — 30 mJ/cm²230V EU (CE7/7)
VH410-F1270 L/min — 30 mJ/cm²230V EU (CE7/7)
VH410-F2270 L/min — 30 mJ/cm²230V EU (CE7/7)
VH200-V29.5 L/min — 16 mJ/cm²120V (NEMA 5-15P)
VH410-V53 L/min — 16 mJ/cm²120V (NEMA 5-15P)
VH410M-V53 L/min — 16 mJ/cm²120V (NEMA 5-15P)

VH200-F10 — 120 V power supply

0.00 € 0.00 €
678.50 €
  • Model / power supply

Product and operation

High-output UV

Constant-current control

Sensor on M versions

High-output lamp technology keeps the treatment chamber compact. The model-specific specifications distinguish the flow available at each UV dose.

Constant lamp current supports stable UV output despite fluctuations in the electrical supply.

A UV sensor is included on the models carrying the M designation, giving direct feedback on UV performance. Other versions retain their own documented control configuration.

The controller displays the lamp countdown and provides audible indications for lamp replacement and lamp failure.

VIQUA VH

VH150VH200VH410
Flow / UV dose — 16 mJ/cm²45 L/min60 L/min130 L/min
Flow / UV dose — 30 mJ/cm²19 L/min34 L/min70 L/min
Dimensions (manufacturer)33 cm x 8.9 cm45 cm x 8.9 cm59.6 cm x 8.9 cm
Connections3/4″- 1″ MNPT (/2B – BSP)3/4″- 1″ MNPT (/2B – BSP)3/4″- 1″ MNPT (/2B – BSP)
Power consumption32W35W60W
Shipping weight8 lbs (3.6 kg)12 lbs (5.4 kg)17 lbs (7.7 kg)
Power supply230V EU (CE7/7)230V EU (CE7/7)230V EU (CE7/7)
ModelCharacteristicValue
VH200Flow / UV dose — 40 mJ/cm²26 L/min
VH410Flow / UV dose — 40 mJ/cm²54 L/min
VH410M
Flow / UV dose — 16 mJ/cm²130 L/min
Flow / UV dose — 30 mJ/cm²70 L/min
Dimensions (manufacturer)59.6 cm x 8.9 cm
Connections3/4″ – 1″ NPT (/2B – BSP)
Power consumption60W
Shipping weight17 lbs (7.7 kg)
Power supply230V EU (CE7/7)
Flow / UV dose — 40 mJ/cm²54 L/min

VIQUA VH F

VH200-F10 and VH410-F20 include sediment prefiltration. The F12 and F22 configurations combine sediment and carbon-block cartridges ahead of the UV chamber.

Water flows through the chamber around the lamp sleeve. UV exposure treats the water without adding a chemical disinfectant; the rated flow is specific to the stated UV dose.

VIQUA VH F

VH200-F10VH410-F20VH200-F12
Flow / UV dose — 16 mJ/cm²60 L/min130 L/min60 L/min
Flow / UV dose — 30 mJ/cm²34 L/min70 L/min34 L/min
Flow / UV dose — 40 mJ/cm²26 L/min54 L/min26 L/min
Dimensions (manufacturer)43 cm x 26 cm x 45 cm43 cm x 26 cm x 71 cm63.75 cm x 29.21 cm x 46.74 cm
ModelCharacteristicValue
VH200-F10Connections1″MNPT INLET / 1″ x 3/4″ OUTLET (/2B – BSP)
VH200-F10Power consumption35W
VH200-F10Shipping weight26 lbs (11.8 kg)
VH410-F20Connections1″MNPT INLET / 1″ x 3/4″ OUTLET (/2B – BSP)
VH410-F20Power consumption60W
VH410-F20Shipping weight32 lbs (14.5 kg)
VH200-F12Inlet3/4 in. FNPT
VH200-F12Outlet3/4 in. FNPT, 1 in. MNPT
VH410-F12VH410-F22
Flow / UV dose — 16 mJ/cm²120 L/min120 L/min
Flow / UV dose — 30 mJ/cm²70 L/min70 L/min
Flow / UV dose — 40 mJ/cm²54 L/min54 L/min
Dimensions (manufacturer)63.75 cm x 29.21 cm x 71.63 cm63.75 cm x 29.21 cm x 71.63 cm
Inlet3/4 in. FNPT3/4 in. FNPT
Outlet3/4 in. FNPT, 1 in. MNPT3/4 in. FNPT, 1 in. MNPT

VIQUA VH-V

NSF/ANSI 55 Class B concerns supplemental bactericidal treatment of water already disinfected or tested and accepted as drinking water. These systems are not intended to make contaminated water potable.

VIQUA VH-V

VH200-VVH410-VVH410M-V
Flow / UV dose — 16 mJ/cm²29.5 L/min53 L/min53 L/min
Dimensions (manufacturer)45 cm x 8.9 cm59.6 cm x 8.9 cm59.6 cm x 8.9 cm
Connections3/4″FNTP- 1″ MNPT (/2B – BSP)3/4″FNPT- 1″ MNPT (/2B – BSP)3/4″FNPT- 1″ MNPT (/2B – BSP)
Power consumption35W60W60W
Shipping weight12 lbs (5.4 kg)17 lbs (7.7 kg)17 lbs (7.7 kg)

Specifications

Model / power supply VH150 — 230V EU (CE7/7), VH200 — 230V EU (CE7/7), VH410 — 230V EU (CE7/7), VH410M — 230V EU (CE7/7), VH200-F10 — 230V EU (CE7/7), VH410-F20 — 230V EU (CE7/7), VH200-F12 — 230V EU (CE7/7), VH410-F12 — 230V EU (CE7/7), VH410-F22 — 230V EU (CE7/7), VH200-V — 120V (NEMA 5-15P), VH410-V — 120V (NEMA 5-15P), VH410M-V — 120V (NEMA 5-15P)