VIQUA SHF-290 — UV water treatment

The VIQUA SHF-290 is a UV water treatment system. The manufacturer publishes a reference flow of 813 L/min at 40 mJ/cm². Selection depends on the application, peak flow and water analysis.

Flow at 40 mJ/cm²

813 L/min

Flow at 30 mJ/cm²

1,098 L/min

UV chamber dimensions

108 × 20.3 × 43.5 cm

SHF flow values apply at 95% UVT and 20 °C, at the end of lamp life.

0.00 € 0.00 €
25,294.25 €
  • Reference UV transmittance (UVT)
  • Reference test temperature
  • Lamp condition for rated flow
  • Manufacturer
  • UV flow at 40 mJ/cm²
  • UV flow at 30 mJ/cm²
  • UV chamber dimensions — manufacturer order
  • Water temperature
  • Power consumption
  • Maximum operating pressure
  • Number of UV lamps
  • Chamber material

Use and sizing

At 95% UVT and 20 °C, at the end of lamp life, the published flows are 813 L/min at 40 mJ/cm² and 1098 L/min at 30 mJ/cm². Select the required dose and check the water analysis before using either value for sizing.

Installation

The SHF-290 has 5 lamps and a 316L stainless-steel chamber. The specified water temperature range is 2–40 °C, with a maximum operating pressure of 8.62 bar. Allow space around the chamber for the maintenance operations described in the manual.

Maintenance

The UV lamp and quartz sleeve are service components. Follow the model-specific manual for inspection, cleaning and replacement, and provide access to the chamber and controller during installation.

Technical specifications

SHF flow values apply at 95% UVT and 20 °C, at the end of lamp life.

Model

SHF-290

Manufacturer reference

SHF-290/2

Flow at 40 mJ/cm²

813 L/min

Flow at 30 mJ/cm²

1,098 L/min

UV dose

40 mJ/cm²

UV chamber dimensions

108 × 20.3 × 43.5 cm

Power consumption

550 W

Maximum operating pressure

8.62 bar

Water temperature

2–40 °C

Connection size

4 ″

Number of lamps

5

Chamber material

316L

Reference UV transmittance (UVT)

95 %

Frequently asked questions

Use 813 L/min at 40 mJ/cm² or 1098 L/min at 30 mJ/cm² only with the stated reference conditions and the dose required by the application.

The SHF-290 uses 5 UV lamps. Identify replacement components by the exact system reference, SHF-290/2.

Use reference SHF-290/2 and the parts list in the model-specific manufacturer manual. Match the lamp, sleeve and controller to that system.

Specifications

Reference UV transmittance (UVT) 95 %
Reference test temperature 20 °C
Lamp condition for rated flow End of lamp life
Manufacturer VIQUA
UV flow at 40 mJ/cm² 813 L/min
UV flow at 30 mJ/cm² 1098 L/min
UV chamber dimensions — manufacturer order 108 × 20.3 × 43.5 cm
Water temperature 2–40 °C
Power consumption 550 W
Maximum operating pressure 8.62 bar
Number of UV lamps 5
Chamber material 316L